Product Details:

TypeAutomatic
Supply90 to 240 VAC +- 10% (5VA), 50/60Hz
Size96 x 96 x 160 mm.
EnclosureMetal Powder coated.
Digit Display SizeSingle Display

With Manual tuning of PID values, our product microprocessor based ten profile ramp/soak Programmable PID Temperature Controller is available at industry leading prices.

Model PRC-309 and PRC-310
DesignMicrprocessor based 8 bit with 12 bit ADC and 8 bit DAC
InputThermocouple type J, K, R, S, B, C, D or RTD(Pt-100)/2 or 3-wire, (4-20)mA, (1000 to 1200)mV, (0-5)V etc. (anyone to be specified).
RangeSubject to the full range of the specified input.
Resolution0.1 / 1°C Subject to the specified input and range.
AccuracyBetter than ± 0.1% of the specified range.
Display4 digit 0.5” Red 7-segment LED display for process value 4 digit 0.3” Red 7-segment LED display for set value
TuningManual Tuning of PID values.
Control ActionPID or On/Off (for both direct and reverse action).
No. of Profiles / Patterns1 to 10.(Format1 : SP0 – t1 – SP1 – t2 – SP3 – t3 … till SP16) (Format2 : PL0 – Pr1 – Pd1, PL1 – Pr2 – Pd2, … till PL16). One or More profile
No. of Ramp/Soak Steps per profile1 to 16 Steps. (no restriction in programming – that ramp should be followed by soak or vice versa)
Set TemperatureProgrammable for each step in the full range of the specified input
Time per Step1 to 540 mins. (9 Hrs. per step). Or 1 minute to 100 hours (Two or more steps can be combined for longer time duration).
Program Hold FacilityManual Hold or Auto Hold (Hold back feature for guaranteed Ramp/Soak facility).
Memory BackupRetention of PID and set values in the non-volatile memory in the event of power failure.
Alarm OutputHigh or Low or Event Alarm Relay (5A @ 230VAC).
Control OutputDC pulses to drive external SSR, Built in Triac (5A @ 230VAC) or (4-20)mA or (0-5)VDC output with soft start and power limit.