Libratherm Instruments Pvt. Ltd.Libratherm Instruments Pvt. Ltd.

Digital and Microcontroller based Temperature / Process Indicator and Controller

Line

Single and Multi loop PID Temperature / Process Controller

Line

Single Zone and 2 to 8 Zone Ramp/Soak Programmable PID Temperature Controller

Line

Temperature / Process Scanner, Data Loggers and Data Acquisition Software

Line

Humidity and Temperature Indicator, Controller, Transmitter and Logger

Line

Signal Isolators / Converter, Two Wire Temperature Transmitters

Signal Isolator / Converter DIN Rail ModulesTwo Wire Head Mount, Field Mount Isolated / Non Isolated Temperature TransmitterMicrocontroller based ISOLATED Temperature Process Transmitter with Local Display

Line

Thyristor Power Controller

Line

Molten Metal Temperature Indicator

Line

Send us bulk enquiry...

Showcase

View all our products / services as a slide show.

play now





Signal Isolators / Converter, Two Wire Temperature Transmitters
Our products are Signal Isolators / Converter, Two wire Temperature Transmitters are used for inputs that required calibration range. The products includes -
Signal Isolator / Converter DIN Rail Modules
Large View


Signal Isolator / Converter DIN Rail Modules

With maximum 4 parallel independent outputs signal isolator and converter din rail modules can provide single input.
Design Based on F/V and V/F linear circuit.
Input types DC input - RTD (Pt-100) / 2 or 3 wire or Thermocouple (All Types – type to be specified) or mV, mA input or Load cell, pressure sensor, pH/ORP sensor etc. generating DC current or voltage. AC input - Current (through external CT) (0-1)A or (0-5)A or Voltage (0-110)VAC or (0-230)VAC or 415VAC Frequency input DC levels of clock pulses of max. 10KHZ. @ (12-24)VDC
Range User may specify the required temperature range (for RTD or T/C input). For other inputs the required calibration range can be specified.
Output (4-20) mA, (0-20) mA, (0-1) VDC, (0-5) VDC, (0-10) VDC, Frequency (0-1)KHz, (0-5)KHz, (0-10)KHz etc. proportional to the specified input range. For current output, RL (max.) = 500 Ohms. For voltage output, RL (min) = 10K Ohms.
No. of Outputs Maximum 4 parallel independent outputs can be provided for single input.
Accuracy For Thermocouple and RTD Input, the calibration of output is done for the best straight line fit to give accuracy of +/- 0.5% of the range. For other input the linearity depends on the input signal, where output accuracy is absolute to the input.
Calibration On site calibration facility through ZERO and SPAN presets accessible to the user.
Isolation Input and Output are optically isolated for DC and frequency inputs and galvanically isolated for the AC inputs.
Isolation Voltage Greater than 2KV.
Mounting 35-mm. DIN rail mounting ABS enclosure.
Supply 90 -260 VAC, 50/60Hz or 24VDC @ 200mA
Size 65(W) x 80(H) x 125(D) mm.
Send Enquiry
Two Wire Head Mount, Field Mount Isolated / Non Isolated Temperature Transmitter
Large View

Two Wire Head Mount, Field Mount Isolated / Non Isolated Temperature Transmitter

The two wire temperature transmitter head mount, field mount isolated and non isolated temperature transmitter are built in red LED indicates the continuity status of the loop.
Input Thermocouple, mV, RTD (Pt-100) or resistance signal from displacement, position or level sensor.
Range Subject to specified input (User should specify the required range).
Output (4-20)mA, two wire and loop powered (calibrated linearly to the input signal).
Options for Output 3 wire version with (4-20) mA on 2mwire loop with separate supply ground can also be provided. 4 wire version with 2 wire for DC supply and 2 wire for (4-20) mA can also be provided.
Accuracy ± 0.5 % of the calibrated span or better including linearity, Hysterisis, and compensation error.
Calibration On site using ZERO / SPAN presets. Zero Adjustment - +/-25% of the range (20 Turns). Span Adjustment - +/- 25% of the range (20 Turns).
Loop supply 24VDC nominal (12 to 36)VDC.
Loop Status The built in Red LED indicates the continuity status of the loop.
Loop Resistance 600 Ohms @ 24VDC (loop supply dependent).
Max. Load Resistance RL Max = (Vs-12V) / 20 mA.
Isolation Input and Output are Galvanically isolated (2KV) for isolated models (LTX-3000/DI and LTX-3000/WI)
Burn Out Detection The output shall saturate > 20mA (max. 25mA @ 24VDC loop supply)
Operating Temp. 10°- 70°
Mounting Standard or Flameproof head, 35 mm DIN rail or on-field in weatherproof enclosure.
Size 44 Dia x 26 mm. Mounting holes at 33 mm on dia. (LTX-3000/H) 22 x 75 x 100 mm (LTX-3000/D) and (LTX-3000/DI) 80 x 80 x 57 mm (LTX-3000/W) and (LTX-3000/WI)
Send Enquiry
Microcontroller based ISOLATED Temperature Process Transmitter with Local  Display
Large View


Microcontroller based ISOLATED Temperature Process Transmitter with Local Display

Our range of Micro controller based ISOLATED Temperature and Process Transmitter with Local Display & RS485 interface in IP65 enclosure are available with Local Display and RS485 interface in IP65 enclosure. Model PTX-3000
Design Microcontroller based (8 bit) with 12 bit ADC and 12 bit dual DAC
Input Sensor J,K,R,S,B thermocouple or RTD (Pt-100) or mV, mA signal
Range Full range of the selected input – desired measuring range can be specified by the user.
Accuracy Software linearized to +/-1°C for thermocouple input and +/-0.1°C for Pt-100 input. For other inputs – the accuracy is absolute to the input.
Supply Voltage 24VDC @ 200mA (12 to 36VDC)
Output 1 4-20mA proportional to the specified range of the user selected input or the specified input. (12 bit resolution). Isolated from Supply voltage
Output 2 4-20mA proportional to the specified range of the second specified input. (12 bit resolution). Isolated from Supply voltage (2nd output is available for two input model PTX-3000/TD
Loop Resistance RLmax = 150 Ohms with internal 5VDC supply and RLmax = 600 Ohms when external 24VDC is used – This 24VDC must be different from Supply voltage.
Display 4 digit each - 0.3” red seven segment LED. 4 digit each for two input models.
Connection 5 wire connection for supply and current output
Serial Communication Isolated 2 wire RS485 MODBUS RTU Slave protocol (MODBUS ID is keyboard programmable)
Enclosure (Size) ABS plastic IP-65 (120 x 80 x 55) mm.
Model Description
PTX-3000/UD Process Transmitter – with universal input and local display
PTX-3000/TD Process Transmitter – with two fixed input and local display
PTX-3000/FD Process Transmitter – with single fixed input and local display
Send Enquiry


Contact us
Mr. Kamlesh Panchal
No. 401/402, Diamond Industrial Estate, Ketki Pada Road,, Dahisar East
Mumbai, Maharashtra - 400 068, India
Telephone:  +(91)-(22)-28964769/ 28963823

Contact via E-mail

Contact via Mobile

Contact via SMS



© Libratherm Instruments Pvt. Ltd., All Rights Reserved. (Terms of Use)