Showcase
View all our products / services as a slide show.
play now
|
 |
Temperature / Process Scanner, Data Loggers and Data Acquisition Software
|
We have a wide range of digital and microprocessor based temperature scanner, process scanner, data loggers and data acquisition software, its specifications are as follows -
|
 |  |  |  |  |
 | Microprocessor based 1 to 16 channel or 1 to 32 channel Temperature / Process Scanner Our range of microprocessor based 1 to 16 channel or 1 to 32 channel temperature and process scanner comes with 2 nos. potential free change over contacts. Model MSI - 8000 | Design | Microprocessor based 8 bit with 12 bit ADC and 8 bit DAC | | No. Of channels | 4, 8, 12 or 16 | | Input | J, K, R, S, B, C, D, RTD(PT-100), RTD(PT-1000)/2 or 3 wire, (4-20)mA, (0-1)V etc. (each channel can be of different type) | | Range | -200 to 2000 oC Subject to the specified input | | Accuracy | Better than ± 0.1o, ± 1 o- (Range dependent) Software Linearized | | CJC | Automatic built-in from the range (0-50) o | | Resolution | 0.1o, 1 o(Range dependent) | | Display | 4 digit each 0.5" 7-segment Red LED to display Process & Alarm values, 2 digit 0.5" 7-segment Red LED for channel no | | Open Sensor Indication | Display shows Flt-1 or Flt-2 and Alarm relays will be turned OFF | | Scan Rate | 1 to 99 sec (programmable through front panel keyboard) | | Skip/Hold Facility | Available through key board in configuration mode | | Key board | 6 x 1 soft key membrane keypad for data entry | | High / Low Alarm | Settable using key pad | | Common Relay output | 2 nos. potential free change over contacts (1 each for high and low output but common for all the channels) | | Alarms Output | 2 per channel i.e. 32 open collector outputs to drive external relay card. Can be provided as LL, HH, LH, HL alarm & trip Logic. | | LED Indication | 32 LED's in the front indicating status of each alarm output | | Size | 192 x 96 x 200 mm | | Panel Cutout | 186 x 92 mm., ± 0.5 mm | | Supply | 230VAC / 110 VAC ± 10% (10VA), 50/60Hz or 24VDC @ 500mA | | Enclosure | Metallic with ABS bezel and polycarbonate front | |  |
 |  |  |  |  |

| Microprocessor based 1 to 16 channel or 1 to 32 channel Temperature / Process Data Logger Microprocessor based 1 to 16 channel or 1 to 32 channel Temperature and Process Data Logger are available through key board in configuration modes. Model DATLOG-16/H or DATLOG-16/V | Design | Microprocessor based( 8 bit) with 12 bit ADC and 8 bit DAC | | No. Of channels | 4, 8, 12 or16 can be expanded upto 32 channels. | | Input | J, K, R, S, B, C, D, RTD(PT-100), RTD(PT-1000)/2 or 3 wire, (4-20)mA, (0-1)V etc. (each channel can be of different input type) | | Range | -200 to 2000oC Subject to the specified input | | Accuracy | Better than ± 0.1o, ± 1 o- Software Linearized. | | Resolution | 0.1o, 1o | | Display | 4 digit each 0.5" 7-segment red LED to display process and set values 2 digit 0.5" 7 segment red LED for channel no 6 digit 0.5" 7 segment green LED for real time clock | | Open Sensor Indication | Display shows Flt-1 or Flt-2 and relays will be turned OFF | | Scan Rate | 1 to 99 sec (programmable through front panel keyboard) | | Skip/Hold Facility | Available through key board in configuration mode | | Key board | 6 x 1 soft key membrane keypad for data entry | | Common Relay outputs | 2 nos. potential free change over contact available (1 each for high and low output but common for all the channels) | | Individual Alarm Outputs | 2 per channel i.e. 32 open collector outputs to drive external relay card. Can be provided as LL, HH, LH, HL alarm & trip Logic | | LED Indication | 32 LED's in the front indicating status of each alarm output | | Data Logging | Real Time with Programmable log time and storage time | | Serial / Parallel Interface | Parallel Centronics printer output port for Printer and Serial (RS232/RS485) for PC with Window based software on Modbus ASCII Protocol | | Data Storage | 2K to 128K memory bank | | Size | 192 x 96 x 200 mm (DATLOG-16/H) or 96 x 192 x 200 mm. (DATALOG-16/V) | | Panel Cutout | 186 x 92 mm., or 92 x 186 mm ± 0.5 mm | | Supply | 230VAC / 110 VAC ± 10% (10VA), 50/60Hz or 24VDC @ 500mA | | Enclosure | Metallic with ABS bezel and polycarbonate front fascia | |  |
 |  |  |  |  |

| Data Acquisition Software (Windows based) In the era of computerization, the user friendliness and the usability of the computer is very common aspect in the industry. Computers are widely used for the majority of the industrial applications. In order to use the benefit and power of the PC, Libratherm offers standard, customized and dedicated computer programs or the software which runs on the window based operating platform in connection with the various Libratherm make temperature and process controllers, programmers and Data loggers to monitor the online process behaviour. Though, various industrial well known SCADA software package also do the job of PC interfacing, we still prefer to offer our own dedicated DAS software for the reason of our ability of customization, low cost and modification of the required hardware to meet the end users applications - when compared to the SCADA package. The various microprocessor and microcontroller based instruments are interfaced with the PC on RS232 serial port or RS485 bus having MODBUS RTU or ASCII protocol. Brief description of some of the software is described below: DATALOG16 software – designed to interface with our DATALOG-16, monitors and displays the process value of all 16 channels – which are updated every 1 second. Facility to view the real time line graph of the process values, where user can select or deselect the channel, can zoom in or zoom out with auto scaling of x or y co-ordinates, the data base is created in back ground which can also be seen in the tabular format with real time and date. The records can be easily searched by date, time or by the customized and user selectable field. The software can be customized to group the monitoring of single or multiples systems with suitable identifications. Other software versions such as HTLOGGER software to interface with Humidity and Temperature logger is also available. |  |
|