Product Details:
Brand | Libratherm |
Model No. | DPC-966 (Part No.: 1402-1-1) |
Size | 96 x 96 mm |
Control Type | On-Off |
Input Type | Voltage (mV), RTD, Thermocouple, Current (mA) |
Control output Type | Relay/SSR, Analog (mA/mV) |
Country of Origin | Made in India |
DPC-966: Temperature and Process Controller
I/O Configuration: (1 AI + 1 AO + 2DO + 1 SO) / (1 AI + 1 AO + 4DO + 1 SO)
Description
DPC-966 (Part No 1402): This On-Off Controller is available in the size of 96w x 96h x 120d mm, accepts input from J, K, R, S, B thermocouple, Pt-100, 4-20mA, and provides 2 relay output and/or 2 SSR output along with retransmission of 4-20mA and serial output of RS485 MODBUS interface.
DPC-966 (Part No 1403): This On-Off Controller is available in the size of 96w x 96h x 120d mm, accepts input from J, K, R, S, B thermocouple, Pt-100, 4-20mA, and provides 4 relay output and/or 4 SSR output along with retransmission of 4-20mA and serial output of RS485 MODBUS interface.
DPC-966-T (Part No 1404): This dual input On-Off Controller is available in the size of 96w x 96h x 120d mm, accepts two input from J, K, R, S, B thermocouple, Pt-100, 4-20mA and provides 4 relay output and/or 4 SSR output along with dual retransmission of 4-20mA and serial output of RS-485 MODBUS interface. Both the Input types are not user-selectable but users need to specify.
Key Features:- Microcontroller based Design
- Single input and Two independent input
- Software linearized for better measurement accuracy
- Available in all standard 1/4 DIN sizes
- Works on universal 90-240VAC
- Universal and User selectable input from process transmitters/temperature sensors
- 2 to 4 Relay or SSR Output
- Industrial standard Analog and Digital Interface
Configuration:AI | Analog Input from Process transmitter in the form of 4-20mA or from the Temperature Sensors. |
AO | Analog Output proportional to Analog input, available in the form of Retransmission output of 4-20mA or optionally 0-10V. |
DO | Digital Output in the form of relay contacts or 10 to 12 VDC logic level for external SSR. |
SO | Serial Output in the form of RS-485 on MODBUS RTU interface. |
Ordering Information:Model | Specifications | Part No. |
---|
DPC-966 | Input: J,K,Pt-100,4-20mA + 2 relay/SSR output | 1402-1-1 |
DPC-966 | Input: J,K,Pt-100,4-20mA + 2 relay/SSR output + (4-20)mA | 1402-1-2 |
DPC-966 | Input: J,K,Pt-100,4-20mA + 2 relay/SSR output + RS-485 | 1402-1-3 |
DPC-966 | Input : R,S,B + 2 relay and / or SSR output | 1402-2-1 |
DPC-966 | Input : R,S,B + 2 relay and / or SSR output + (4-20)mA | 1402-2-2 |
DPC-966 | Input : R,S,B + 2 relay / SSR output + RS-485 | 1402-2-3 |
DPC-966 | Input: J,K,Pt-100,4-20mA + 4 relay/SSR output | 1403-1-1 |
DPC-966 | Input: J,K,Pt-100,4-20mA + 4 relay/SSR output + (4-20)mA | 1403-1-2 |
DPC-966 | Input: J,K,Pt-100,4-20mA + 4 relay/SSR output + RS-485 | 1403-1-3 |
DPC-966 | Input : R,S,B + 4 relay and / or SSR output | 1403-2-1 |
DPC-966 | Input : R,S,B + 4 relay and / or SSR output + (4-20)mA | 1403-2-2 |
DPC-966 | Input : R,S,B + 4 relay / SSR output + RS-485 | 1403-2-3 |
DPC-966-T | Input1 & Input2 : User to specify + 4 relay and / or SSR output | 1407-1 |
DPC-966-T | Input1 & Input2 : User to specify + 4 relay and / or SSR output + dual (4-20)mA | 1407-2 |
DPC-966-T | Input1 & Input2 : User to specify + 4 relay / SSR output + RS-485 | 1407-3 |