Libratherm offers various models of Digital Temperature and Process On/Off Controllers. User has the choice of selecting the model based on the type of input, type of analog or digital interface, and required size. All the models are designed to suit most of the Industrial Applications.
This Digital On-Off Safety Controller is available in the size of 48 x 48 x 120 mm, accepts input from J, K, R, S, B thermocouple, Pt-100, 4-20mA and provides 2 relay output or 2 SSR output along with retransmission of 4-20mA and serial output of RS485 MODBUS interface.
₹ 4988 / Number Get Latest Price
| Control Type | On-Off |
| Brand | Libratherm |
| Model No. | DPC-480 (Part No.: 1401-1-1 |
| Size | 48 x 48 mm |
| Input Type | Thermocouple, RTD |
| Control output Type | Relay/SSR |
| Country of Origin | Made in India |
| AI | Analog Input from Process transmitter in the form of 4-20mA or from the Temperature Sensors. |
| AO | Analog Output proportional to Analog input, available in the form of Retransmission output of 4-20mA or optionally 0-10V. |
| DO | Digital Output in the form of relay contacts or 10 to 12 VDC logic level for external SSR. |
| SO | Serial Output in the form of RS-485 on MODBUS RTU interface. |
| Sr. No. | Specifications | Part No. |
|---|---|---|
| 1.1 | Input : J,K,Pt-100,4-20mA + 2 relay or 2 SSR output | 1401-1-1 |
| 1.2 | Input : J,K,Pt-100,4-20mA + 2 relay or 2 SSR output with (4-20)mA retransmission | 1401-1-2 |
| 1.3 | Input : J,K,Pt-100,4-20mA + 2 relay or 2 SSR output with RS-485 interface | 1401-1-3 |
| 1.4 | Input : R,S,B + 2 relay or 2 SSR output | 1401-2-1 |
| 1.5 | Input : R,S,B + 2 relay or 2 SSR output with (4-20)mA retransmission | 1401-2-2 |
| 1.6 | Input : R,S,B + 2 relay or 2 SSR output with RS-485 interface | 1401-2-3 |
₹ 5513 / Number Get Latest Price
| Control Type | On-Off |
| Brand | Libratherm |
| Model No. | DPC-966 (Part No.: 1402-1-1) |
| Size | 96 x 96 mm |
| Input Type | Thermocouple, Current (mA), RTD, Voltage (mV) |
| Control output Type | Relay/SSR, Analog (mA/mV) |
| Country of Origin | Made in India |
| AI | Analog Input from Process transmitter in the form of 4-20mA or from the Temperature Sensors. |
| AO | Analog Output proportional to Analog input, available in the form of Retransmission output of 4-20mA or optionally 0-10V. |
| DO | Digital Output in the form of relay contacts or 10 to 12 VDC logic level for external SSR. |
| SO | Serial Output in the form of RS-485 on MODBUS RTU interface. |
| Model | Specifications | Part No. |
|---|---|---|
| DPC-966 | Input: J,K,Pt-100,4-20mA + 2 relay/SSR output | 1402-1-1 |
| DPC-966 | Input: J,K,Pt-100,4-20mA + 2 relay/SSR output + (4-20)mA | 1402-1-2 |
| DPC-966 | Input: J,K,Pt-100,4-20mA + 2 relay/SSR output + RS-485 | 1402-1-3 |
| DPC-966 | Input : R,S,B + 2 relay and / or SSR output | 1402-2-1 |
| DPC-966 | Input : R,S,B + 2 relay and / or SSR output + (4-20)mA | 1402-2-2 |
| DPC-966 | Input : R,S,B + 2 relay / SSR output + RS-485 | 1402-2-3 |
| DPC-966 | Input: J,K,Pt-100,4-20mA + 4 relay/SSR output | 1403-1-1 |
| DPC-966 | Input: J,K,Pt-100,4-20mA + 4 relay/SSR output + (4-20)mA | 1403-1-2 |
| DPC-966 | Input: J,K,Pt-100,4-20mA + 4 relay/SSR output + RS-485 | 1403-1-3 |
| DPC-966 | Input : R,S,B + 4 relay and / or SSR output | 1403-2-1 |
| DPC-966 | Input : R,S,B + 4 relay and / or SSR output + (4-20)mA | 1403-2-2 |
| DPC-966 | Input : R,S,B + 4 relay / SSR output + RS-485 | 1403-2-3 |
| DPC-966-T | Input1 & Input2 : User to specify + 4 relay and / or SSR output | 1407-1 |
| DPC-966-T | Input1 & Input2 : User to specify + 4 relay and / or SSR output + dual (4-20)mA | 1407-2 |
| DPC-966-T | Input1 & Input2 : User to specify + 4 relay / SSR output + RS-485 | 1407-3 |
₹ 3938 / Number Get Latest Price
| Control Type | On-Off |
| Brand | Libratherm |
| Model No. | DPC-912 ( Part No.: 1404-1) |
| Size | 96 x 48 mm |
| Input Type | RTD, Thermocouple, Current (mA), Voltage (mV) |
| Control output Type | Relay/SSR, Analog (mA/mV) |
| Country of Origin | Made in India |
| AI | Analog Input from Process transmitter in the form of 4-20mA or from the Temperature Sensors. |
| AO | Analog Output proportional to Analog input, available in the form of Retransmission output of 4-20mA or optionally 0-10V. |
| DO | Digital Output in the form of relay contacts or 10 to 12 VDC logic level for external SSR. |
| SO | Serial Output in the form of RS-485 on MODBUS RTU interface. |
| Sr. No. | Specifications | Part No. |
|---|---|---|
| 1.1 | Input : J,K,Pt-100,4-20mA + 2 relay or 2 SSR output | 1404-1 |
| 1.2 | Input : J,K,Pt-100,4-20mA + 2 relay or 2 SSR output with 4-20mA retransmission | 1404-2 |
₹ 3938 / Number Get Latest Price
| Control Type | On-Off |
| Brand | Libratherm |
| Model No. | DPC-913 (Part No.: 1405-1) |
| Size | 48 x 96 mm |
| Input Type | Voltage (mV), Thermocouple, RTD, Current (mA) |
| Control output Type | Analog (mA/mV), Relay/SSR |
| Country of Origin | Made in India |
| AI | Analog Input from Process transmitter in the form of 4-20mA or from the Temperature Sensors. |
| AO | Analog Output proportional to Analog input, available in the form of Retransmission output of 4-20mA or optionally 0-10V. |
| DO | Digital Output in the form of relay contacts or 10 to 12 VDC logic level for external SSR. |
| SO | Serial Output in the form of RS-485 on MODBUS RTU interface. |
| Sr. No. | Specifications | Part No. |
|---|---|---|
| 1.1 | Input : J,K,Pt-100,4-20mA + 2 relay or SSR output | 1405-1 |
| 1.2 | Input : J,K,Pt-100,4-20mA + 2 relay/SSR output with 4-20mA retransmission | 1405-2 |
₹ 3938 / Number Get Latest Price
| Control Type | On-Off |
| Brand | Libratherm |
| Model No. | DPC-903 ( Part No.: 1406-1) |
| Size | 96 x 96 mm |
| Input Type | Current (mA), RTD, Voltage (mV), Thermocouple |
| Control output Type | Analog (mA/mV), Relay/SSR |
| Country of Origin | Made in India |
| AI | Analog Input from Process transmitter in the form of 4-20mA or from the Temperature Sensors. |
| AO | Analog Output proportional to Analog input, available in the form of Retransmission output of 4-20mA or optionally 0-10V. |
| DO | Digital Output in the form of relay contacts or 10 to 12 VDC logic level for external SSR. |
| SO | Serial Output in the form of RS-485 on MODBUS RTU interface. |
| Sr. No. | Specifications | Part No. |
|---|---|---|
| 1.1 | Input : J,K,Pt-100,4-20mA + 2 relay or 2 SSR output | 1406-1 |
| 1.2 | Input : J,K,Pt-100,4-20mA + 2 relay/SSR output With 4-20mA retransmission | 1406-2 |
Kamlesh Panchal (Managing Director)
Libratherm Instruments Private Limited
No. 401-403, Diamond Industrial Estate, Ketki Pada Road
Mumbai - 400068, Maharashtra, India