Product Details:
Brand | Libratherm |
Model No. | DPC-912 |
Size | 96 x 48 mm |
Control Type | On-Off |
Input Type | RTD, Current (mA), Thermocouple |
Control output Type | Relay/SSR, Analog (mA/mV) |
Display Type | 3 Digit/7 Segment |
Voltage | 110-230 VAC |
Libratherm offers various models of Digital Temperature and Process On/Off Controllers. User has the choice of selecting the model based on the type of input, type of analog or digital interface, and required size. All the models are designed to suit most of the Industrial Applications.
This Digital On/Off Safety Controller is available in the size of 96w x 48h x 75d mm, accepts input from J, K, thermocouple, Pt-100, 4-20mA, and provides 2 relay output or 2 SSR output along with retransmission of 4-20mA.
Key Features:Product Details:
Brand | Libratherm |
Model No. | PID-913 |
Size | 48 x 96 mm |
Control Type | PID |
Input Type | Current (mA), Thermocouple, RTD |
Control output Type | Analog (mA/mV), Relay/SSR |
Display Type | 4 Digit/7 Segment |
Libratherm offers various models of Digital Temperature and Process PID Controllers. The user has the choice of selecting the model based on the type of Input, type of analog or digital interface, and required size. All the models are designed to suit most of the Industrial applications.
This High-Temperature PID Controller is available in the size of 48w x 96h x 75d mm, accepts input from J, K, thermocouple, Pt-100, 4-20mA, and provides SSR output, 4-20mA output, 1 relay output.
Key Features:Product Details:
Minimum Order Quantity | 1 Piece |
Model No. | DPC-480 |
Size | 48 x 48 mm |
Control Type | PID |
Input Type | RTD, Voltage (mV), Thermocouple, Current (mA) |
Control output Type | Relay/SSR, Analog (mA/mV) |
Brand | Libratherm |
Input Sensor | TC type J, K, R, S, B, C, D or RTD(Pt-100) 2 or 3-wire input, (0-10)V and (4-20)mA (Any One) |
Temperature Range | Subject to the full range of the specified input |
Display Type | 4 Digit/7 Segment |
Additional Information:
Product Details:
Minimum Order Quantity | 1 Piece |
Model No. | PID-903 |
Control Type | PID |
Input Type | Thermocouple, RTD, Current (mA) |
Control output Type | Relay/SSR, Analog (mA/mV) |
Brand | Libratherm |
Display Type | 4 Digit/7 Segment |
Model | Product Description | Size w x h x d (mm.) |
PID-903 | Temperature/Process PID controller with Relay/SSR/4-20mA Output | 96 x 96 x 75 |
PID-912 | Temperature/Process PID controller with Relay/SSR/4-20mA Output | 96 x 48 x 75 |
PID-913 | Temperature/Process PID controller with Relay/SSR/4-20mA Output | 48 x 96 x 75 |
Additional Information:
Product Details:
Voltage | 220-240 V |
Control Type | PID On/ Off |
No of digits | 4+7 |
Output type | Relay |
Sensor Input | RTD, Thermocouple |
We are engaged in Libratherm PID-912 PID Temperature Controller.
Libratherm offers various models of Digital Temperature and Process PID Controllers. The user has the choice of selecting the model based on the type of Input, type of analog or digital interface, and required size. All the models are designed to suit most of the Industrial applications.
This Hight-Temperature PID Controller accepts input from J, K, thermocouple, Pt-100, 4-20mA, and provides SSR output, 4-20mA output, 1 relay output.
Key Features:Product Details:
Minimum Order Quantity | 1 Piece |
Model No. | DPI-902 |
Size | 96 x 96 mm |
Control Type | Proportional |
Input Type | RTD, Thermocouple, Current (mA) |
Control output Type | Analog (mA/mV) |
Brand | Libratherm |
Resolution | 1 Deg C for thermocouples and 0.1 Deg C for Pt-100. |
Display Type | 4 Digit/7 Segment |
Voltage | 110-230 VAC |
Model | Product Description | Size w x h x d (mm.) |
DPC-903 | Temperature/Process On-Off or Time proportional controller with Relay/SSR/(4-20)mA retransmission output | 96 x 96 x 75 |
DPC-912 | Temperature/Process On-Off or Time proportional controller with Relay/SSR/(4-20)mA retransmission output | 96 x 48 x 75 |
DPC-913 | Temperature/Process On-Off or Time proportional controller with Relay/SSR/ (4-20)mA retransmission output | 48 x 96 x 75 |
Additional Information:
Product Details:
Model No. | HTC-489 |
Size | 48 x 96 mm |
Control Type | On-Off |
Input Type | RTD, Thermocouple, Current (mA), Voltage (mV) |
Control output Type | Relay/SSR |
Brand | Libratherm |
Display Type | 4 Digit/7 Segment |
Voltage | f 90 to 250 VAC |
Application | Temperature control, Pressure control, Heater bank selection, Star delta changeover, Level control |
Additional Information:
Product Details:
Minimum Order Quantity | 1 Piece |
Brand | Libratherm |
Model No. | HTC-966 |
Size | 96 x 96 mm |
Control Type | On-Off |
Input Type | RTD, Thermocouple |
Temperature Range | Subject to the full range of the specified input |
Display Type | 4 Digit/7 Segment |
Voltage | 110-230 VAC |
Frequency | 50/60 Hz |
Type | Digital |
Additional Information:
Product Details:
Brand | Libratherm |
Model No. | DPI-902 (Part No.: 1304-1) |
Input Type | RTD, Current (mA), Thermocouple |
Accuracy | +/- 1oC for Thermocouple throughout the range and +/- 0.1oC for Pt-100 for (4-20)mA |
Resolution | 0.1,0.01,0.001 |
Mounting Type | Panel |
Country of Origin | Made in India |
DPI-902 – Temperature and Process Indicator.
Configuration: (1 AI + 1 AO )
Size: 96 x 96 x 75
Part No: 1304
Key Features:
AI | Analog Input from Process transmitter in the form of 4-20mA or from the Temperature Sensors. |
AO | Analog Output proportional to Analog input, available in the form of Retransmission output of 4-20mA or optionally 0 -10V. |
SO | Serial Output in the form of RS-485 on MODBUS RTU interface. |
Parametes | Description |
---|---|
Process Input | 4-20mA or 0-10V |
Display Range | -2000 to +2000 or 0 to 4000 count with programmable decimal point |
Resolution | 0.1,0.01,0.001 |
Temperature Input | Thermocouple type – J, K, RTD(Pt-100) or R, S, B thermocouple |
Temperature Range | As shown in the Ordering Information table. |
Resolution | 1oC for thermocouples and 0.1 °C for Pt-100. |
Sampling rate / Display rate | The input is read @40mS / the display is updated @1 second. |
Indicating Accuracy | +/- 1oC for Thermocouple throughout the range and +/- 0.1oC for Pt-100 for (4-20)mA or (0-10)V - absolute to the linear input signal |
Display | 4 digit 0.5" Red 7-segment display for process variable. |
4 digit 0.5" Green 7-segment display for input type. | |
Settings | Using Front panel feather touch key board to set various parameters like span HI/LO values, MODBUS slave ID, Input selection, calibration etc |
Retransmission Output (Analog) | 4-20mA linearized and proportional to the selected input type and range |
Supply | (90VAC-250VAC), 50/60 Hz, 18 to 48VAC/DC (optional) |
Size | 96 x 96 x 75 |
Enclosure | ABS plastic with polycarbonate front graphic. |
Sr. No. | Specifications | Part No. |
---|---|---|
1.1 | Input : J,K,Pt-100,4-20mA | 1304-1 |
1.2 | Input : J,K,Pt-100,4-20mA with 4-20mA retransmission | 1304-2 |
1.3 | Input : R,S,B T/C | 1304-3 |
1.4 | Input : R,S,B T/C + 4-20mA retransmission | 1304-4 |
Product Details:
Brand | Libratherm |
Model No. | DPI-948 (Part No: 1301-1-1) |
Size | 96 x 48 mm |
Model Name/Number | Temperature Indicator - DPI-948 |
Display Type | Digital |
Mounting Type | Panel |
Country of Origin | Made in India |
DPI-948 – Temperature and Process Indicator.
Configuration: (1 AI + 1 AO + 1 SO)
Size: 96 x 48 x 120
Part No: 1301
AI | Analog Input from Process transmitter in the form of 4-20mA or from the Temperature Sensors. |
AO | Analog Output proportional to Analog input, available in the form of Retransmission output of 4-20mA or optionally 0 -10V. |
SO | Serial Output in the form of RS-485 on MODBUS RTU interface. |
Parametes | Description |
---|---|
Process Input | 4-20mA or 0-10V or Any other as required. |
Display Range | -2000 to +2000 or 0 to 4000 count with programmable decimal point |
Resolution | 0.1,0.01,0.001 count |
Temperature Input | Thermocouple type – J, K, RTD(Pt-100) or R, S, B sensor |
Temperature Range | Full +ve range of the selected input type. |
Resolution | 1 °C/0.1 °C for thermocouples and 0.1 °C/0.01 °C for Pt-100. |
Sampling rate / Display rate | The input is read @40mS / the display is updated @1 second. |
Indicating Accuracy | +/- 1 °C for Thermocouple throughout the range and +/- 0.1 °C for Pt-100 for (4-20)mA or (0-10)V - absolute to the linear input signal |
Display | 4 digit 0.33" Red 7-segment display for process variable. 4 digit 0.33" Green 7-segment display for Input type and others. |
Settings | Using Front panel Feather touch key board to set various parameters like Span Hi/Lo values, MODBUS slave ID, Input selection, calibration etc |
Retransmission Output (Analog) | 4-20mA linearized and proportional to the selected input type and range. |
Digital Interface | RS-485 over MODBUS RTU protocol in Slave Mode. |
Supply | (90VAC-250VAC), 50/60 Hz, 18 to 48VAC/DC (optional) |
Size | 96 x 48 x 120 |
Enclosure | ABS plastic with polycarbonate front graphic. |
Sr. No. | Specifications | Part No. |
---|---|---|
1.1 | Input : J,K,Pt-100,4-20mA | 1301-1-1 |
1.2 | Input : J,K,Pt-100,4-20mA with (4-20)mA retransmission | 1301-1-2 |
1.3 | Input : J,K,Pt-100,4-20mA with RS485 interface | 1301-1-3 |
1.4 | Input : R,S,B thermocouple | 1301-2-1 |
1.5 | Input : R,S,B with (4-20)mA retransmission | 1301-2-2 |
1.6 | Input : R,S,B with RS-485 interface | 1301-2-3 |
Product Details:
Brand | Libratherm |
Size | 96 x 96 mm |
Input Type | Current (mA), Thermocouple, RTD |
Model Name/Number | Temperature Indicator - DPI-966 (Part No: 1302-1-1) |
Display Type | Digital |
Mounting Type | Panel |
Country of Origin | Made in India |
DPI-966 – Temperature and Process Indicator.
Configuration: (1 AI + 1 AO + 1 SO)
Size: 96 x 96 x 120
Part No: 1302
AI | Analog Input from Process transmitter in the form of 4-20mA or from the Temperature Sensors. |
AO | Analog Output proportional to Analog input, available in the form of Retransmission output of 4-20mA or optionally 0 -10V. |
SO | Serial Output in the form of RS-485 on MODBUS RTU interface. |
Parametes | Description |
---|---|
Process Input | 4-20mA or 0-10V |
Display Range | -2000 to +2000 or 0 to 4000 count with programmable decimal point |
Resolution | 0.1,0.01,0.001 |
Temperature Input | Thermocouple type – J, K, RTD(Pt-100) or R, S, B thermocouple |
Temperature Range | As shown in the Ordering Information table. |
Resolution | 1oC for thermocouples and 0.1oC for Pt-100. |
Sampling rate / Display rate | The input is read @40mS / the display is updated @1 second. |
Indicating Accuracy | +/- 1oC for Thermocouple throughout the range and +/- 0.1oC for Pt-100 for (4-20)mA or (0-10)V - absolute to the linear input signal |
Display | 4 digit 0.5" Red 7-segment display for process variable. |
4 digit 0.5" Green 7-segment display for input type | |
Settings | Using Front panel feather touch key board to set various parameters like span HI/LO values, MODBUS slave ID, Input selection, calibration etc |
Retransmission Output (Analog) | 4-20mA linearized and proportional to the selected input type and range |
Digital Interface | RS-485 over MODBUS RTU protocol in Slave Mode. |
Supply | (90VAC-250VAC), 50/60 Hz, 18 to 48VAC/DC (optional) |
Size | 96 x 96 x 120 |
Enclosure | ABS plastic with polycarbonate front graphic. |
Sr. No. | Specifications | Part No. |
---|---|---|
1.1 | Input : J,K,Pt-100,4-20mA | 1302-1-1 |
1.2 | Input : J,K,Pt-100,4-20mA with (4-20)mA retransmission | 1302-1-2 |
1.3 | Input : J,K,Pt-100,4-20mA with RS485 interface | 1302-1-3 |
1.4 | Input : R,S,B thermocouple | 1302-2-1 |
1.5 | Input : R,S,B with (4-20)mA retransmission | 1302-2-2 |
1.6 | Input : R,S,B with RS-485 interface | 1302-2-3 |
Product Details:
Brand | Libratherm |
Size | 96 x 96 mm |
Input Type | Thermocouple, RTD, Current (mA) |
Model Name/Number | Temperature Indicator - DPI-966-T (Part No: 1307-1) |
Display Type | Digital |
Mounting Type | Panel |
Country of Origin | Made in India |
DPI-966-T – Temperature and Process Indicator.
Configuration: (2 AI + 2 AO + 1 SO)
Size: 96 x 96 x 120
Part No: 1307
Parametes | Description |
---|---|
Process Input 1 and 2 | 4-20mA or 0-10V |
Display Range | -2000 to +2000 or 0 to 4000 count with programmable decimal point |
Resolution | 0.1,0.01,0.001 |
Temperature Input 1 and 2 | Thermocouple type – J, K, RTD(Pt-100) or R, S, B thermocouple (Any one to be specified by User – and not user selectable) |
Temperature Range | As shown in the Ordering Information table. |
Resolution | 1oC for thermocouples and 0.1oC for Pt-100. |
Sampling rate / Display rate | The input is read @40mS / the display is updated @1 second. |
Indicating Accuracy | +/- 1oC for Thermocouple throughout the range and +/- 0.1oC for Pt-100 for (4-20)mA or (0-10)V - absolute to the linear input signal |
Display | 4 digit 0.5" Red 7-segment display for 1st Input reading. |
4 digit 0.5" Green 7-segment display for 2nd input reading. | |
Settings | Using Front panel feather touch the keyboard to set various parameters like SPAN HI/LO values, MODBUS Slave ID, Input selection, calibration, etc |
Retransmission Output (Analog) | 4-20mA linearized and proportional to the selected input type and range. Available for each Input. (Optional) |
Digital Serial Interface | Optically isolated 2 wire RS485 over Modbus RTU protocol. (Slave mode with programmable Modbus address). (Optional) |
Supply | (90VAC-250VAC), 50/60 Hz, 18 to 48VAC/DC (optional) |
Size | 96 x 96 x 120 |
Enclosure | ABS plastic with polycarbonate front graphic. |
Sr. No. | Specifications | Part No. |
---|---|---|
1.1 | Input1 and Input 2 : J T/C with no interface | 1307-1 |
1.2 | Input1 and Input 2 : J T/C + Dual 4-20mA Retransmission | 1307-2 |
1.3 | Input1 and Input 2 : J T/C + RS-485 interface | 1307-3 |
2.1 | Input1 and Input 2 : K T/C with no interface | 1307-4 |
2.2 | Input1 and Input 2 : K T/C + Dual 4-20mA Retransmission | 1307-5 |
2.3 | Input1 and Input 2 : K T/C + RS4-85 interface | 1307-6 |
3.1 | Input1 and Input 2 : (Pt-100) with no interface | 1307-7 |
3.2 | Input1 and Input 2 : (Pt-100) + Dual 4-20mA Retransmission | 1307-8 |
3.3 | Input1 and Input 2 : (Pt-100) + RS-485 interface | 1307-9 |
4.1 | Input1 and Input 2 : (4-20)mA with no interface | 1307-10 |
4.2 | Input1 and Input 2 : (4-20)mA + Dual 4-20mA Retransmission | 1307-11 |
4.3 | Input1 and Input 2 : (4-20)mA + RS-485 interface | 1307-12 |
Product Details:
Minimum Order Quantity | 1 Piece |
Model No. | DTC-903-R |
Size | 96 x 96 mm |
Control Type | PID/On-Off |
Input Type | Thermocouple, RTD, Current (mA) |
Control output Type | Relay/SSR |
Brand | Libratherm |
Accuracy | 0.2% |
Display Type | 4 Digit/7 Segment |
Voltage | 110-230 VAC |
Frequency | 50/60 Hz |
Country of Origin | Made in India |
Resistence | 0-500 R,0-1/5/10 K,1M |
Display resolution | 1999 to 9999 fully configurable for linear input |
Product Details:
Minimum Order Quantity | 1 Number |
Warranty | 1 Year |
Model | DPI-4000-D |
Brand | Libratherm |
Display Type | Digital |
Usage | Industrial |
Color | RED |
Country of Origin | Made in India |
Additional Information:
Product Details:
Brand | Libratherm |
Model No. | DPI-967 - Temperature and Process Indicator (Part No: 1305) |
Size | 96 x 96 mm |
Input Type | RTD, Current (mA), Thermocouple, Voltage (mV) |
Display Type | 5 Digit/7 Segment |
Mounting Type | Panel |
Country of Origin | Made in India |
DPI-967 – Temperature and Process Indicator.
Configuration: (1 AI + 1 AO + 1 SO)
Size: 96 x 96 x 120
Part No: 1305
AI | Analog Input from Process transmitter in the form of 4-20mA or from the Temperature Sensors. |
AO | Analog Output proportional to Analog input, available in the form of Retransmission output of 4-20mA or optionally 0 -10V. |
SO | Serial Output in the form of RS-485 on MODBUS RTU interface. |
Parametes | Description |
---|---|
Process Input | 4-20mA or 0-10V or Any other as required. |
Display Range | -1999 to +9999 / 0 to 19999 with programmable decimal point |
Resolution | 0.1,0.01,0.001 count |
Temperature Input | Thermocouple type – J, K, RTD(Pt-100) or R, S, B sensor |
Temperature Range | Full +ve range of the selected input type. |
Resolution | 1 °C/0.1 °C for thermocouples and 0.1 °C/0.01 °C for Pt-100. |
Sampling rate / Display rate | The input is read @40mS / the display is updated @1 second. |
Indicating Accuracy | +/- 1 °C for Thermocouple throughout the range and +/- 0.1 °C for Pt-100 for (4-20)mA or (0-10)V - absolute to the linear input signal |
Display | 5 digit 0.5" Red 7-segment display for process variable. 5 digit 0.5" Green 7-segment display for Input type and others. |
Settings | Using Front panel Feather touch key board to set various parameters like Span Hi/Lo values, MODBUS slave ID, Input selection, calibration etc |
Retransmission Output (Analog) | 4-20mA linearized and proportional to the selected input type and range. |
Digital Interface | RS-485 over MODBUS RTU protocol in Slave Mode. |
Supply | (90VAC-250VAC), 50/60 Hz, 18 to 48VAC/DC (optional) |
Size | 96 x 96 x 120 |
Enclosure | ABS plastic with polycarbonate front graphic. |
Sr. No. | Specifications | Part No. |
---|---|---|
1.1 | Input : Pt-100/4-20mA /0-10V with RS485 interface | 1305 |
Product Details:
Minimum Order Quantity | 1 Piece |
Type | Automatic |
No of Inputs | 6 |
Mounting Type | Panel Mount |
Supply | 180 to 250VAC, 50/60 Hz |
Brand | Libratherm |
Size | 192(w) x 96(h) x 200(d)mm. |
Input | 6 nos. of level sensors each of 4 wires (3 + 1 common) |
Sensor Type | Steel or Metallic rods - When two rods are dip in the liquid - the contact is detected to be made |
Relay contacts | Two sets of relay change-over contacts per tank. Both can be operated in the desired logic |
LED display | Front panel LED shows the status of levels and relay outputs. |
Enclosure | Dust free-Metallic powder coated |
Weight | 1.0 Kg (approx) |
Mounting | Flush panel mounting. |
PRODUCT DESCRIPTION:
Libratherm offers six tank liquid level controller model LLC-06, designed to control the liquid level in the six independent tanks. It accepts 4 wire (3 + 1 common) of liquid level sensor in the form of potential free contacts for each tank to detect HI level, MED level and LOW level. Internal electronics circuit monitors the level from the level sensors and displays the status of each using the front panel LEDs. Two sets of 5A @ 230VAC relay contact output is provided for each tank, which can be used to control the Feed pump or the Delivery pump as per the users requirement. The controller operates on 230VAC supply and is available in 1/2 DIN size of 192 x 96 x 200 mm.
LLC-06 finds its application in the industries manufacturing breweries, aerated drinks, fruit juices, pharmaceutical syrups etc... where to prepare final product the different liquids are mixed from the different tanks and maintaining their level is a critical process. The controller featured here can maintain the desired levels of up to six tanks.
Additional Information:
Product Details:
Minimum Order Quantity | 1 Piece |
Display Type | Digital |
Brand | Libratherm |
Model | HTI-966-T |
Two Inputs | Simultaneous - Two independent fixed inputs of the same type can also be used.Available only DTI-966 |
Additional Information:
Product Details:
Brand | Libratherm |
Model No. | DPI-912 (Part No: 1303-1) |
Size | 96 x 48 mm |
Input Type | RTD, Thermocouple, Current (mA) |
Display Type | 4 Digit/7 Segment |
Mounting Type | Panel |
Country of Origin | Made in India |
DPI-912 – Temperature and Process Indicator.
Configuration: (1 AI + 1 AO)
Size: 96 x 48 x 75
Part No: 1303
AI | Analog Input from Process transmitter in the form of 4-20mA or from the Temperature Sensors. |
AO | Analog Output proportional to Analog input, available in the form of Retransmission output of 4-20mA or optionally 0 -10V. |
SO | Serial Output in the form of RS-485 on MODBUS RTU interface. |
Parametes | Description |
---|---|
Process Input | 4-20mA or 0-10V |
Display Range | -2000 to +2000 or 0 to 4000 count with programmable decimal point |
Resolution | 0.1,0.01,0.001 |
Temperature Input | Thermocouple type – J, K, RTD(Pt-100) or R, S, B thermocouple |
Temperature Range | As shown in the Ordering Information table. |
Resolution | 1 °C for thermocouples and 0.1 °C for Pt-100. |
Sampling rate / Display rate | The input is read @40mS / the display is updated @1 second. |
Indicating Accuracy | +/- 1oC for Thermocouple throughout the range and +/- 0.1oC for Pt-100 for (4-20)mA or (0-10)V - absolute to the linear input signal |
Display | 4 digit 0.33" Red 7-segment display for process variable. LED Indications for Input type |
Settings | Using Front panel feather touch key board to set various parameters like span HI/LO values, MODBUS slave ID, Input selection, calibration etc |
Retransmission Output (Analog) | 4-20mA linearized and proportional to the selected input type and range. |
Supply | (90VAC-250VAC), 50/60 Hz, 18 to 48VAC/DC (optional) |
Size | 96 x 48 x 75 |
Enclosure | ABS plastic with polycarbonate front graphic. |
Sr. No. | Specifications | Part No. |
---|---|---|
1.1 | Input : J,K,Pt-100,4-20mA | 1303-1 |
1.2 | Input : J,K,Pt-100,4-20mA with 4-20mA retransmission | 1303-2 |
1.3 | Input : R,S,B T/C | 1303-3 |
1.4 | Input : R,S,B T/C + 4-20mA retransmission | 1303-4 |
Product Details:
Minimum Order Quantity | 1 Piece |
Model No. | HTC-723 |
Control Type | On-Off |
Input Type | Voltage (mV), Thermocouple, Current (mA), RTD |
Control output Type | Relay/SSR |
Brand | Libratherm |
Temperature Range | Subject to the full range of the specified input |
Display Type | 4 Digit/7 Segment |
Frequency | 50/60 Hz |
Additional Information:
Product Details:
Minimum Order Quantity | 1 Piece |
Input Sensor | TC type J,K,R,S,B,C,D or RTD(Pt-100) 2 or 3-wire input,(0-10)V and (4-20)mA (Any One) |
Size | 96 x 48 mm |
Control output Type | Relay/SSR |
Brand | Libratherm |
Display Type | 4 Digit/7 Segment |
Control Type | On-Off |
Model No. | HTC-948 |
Input Type | RTD, Current (mA), Voltage (mV), Thermocouple |
Additional Information: