New Items

Molten Metal Temperature Indicator with Lamp and Hooter Box LLC-2010

Request Callback

₹ 6825 / Number Get Latest Price

Model No.LLC-2010
Usage/Application(Red, Yellow and Green color) for visual indication of Measurement in Progress
Size/Dimension185(w) x 500(h) x 125(d)mm.
BrandLibratherm
Power110 or 230VAC +/-15%, 50/60 Hz (Aux. supply is not required)
Weight10.0 Kg (approx.)
Model Name/NumberLLC-2010 (Part No.: 3505)
LLC-2010 – Molten Metal Temperature Indicator with Lamp and Hooter Box.
Technical Specifications
ParametersDescription
Contact Inputs 4 nos. of C-NO potential free contacts from LMI-2010
Audio/Visual Indication. 4 nos. of bright lamps (Red, Yellow and Green color) for visual indication of Measurement in Progress, Measurement Over, Thermocouple Continuity, and a Hooter at the END of Measurement.
Supply 110 or 230VAC +/-15%, 50/60 Hz (Aux. supply is not required)
Enclosure Dust-free – Metallic powder coated
Size 185(w) x 500(h) x 125(d)mm.
Weight 10.0 Kg (approx.)
Mounting Wall mounting key.

Ordering Information

Sr. No.ModelSpecificationsPart No.
1.1 LLC-2010 Lamp + Hooter Box
(Works only on Relay Contacts from LMI-2010)
(to be ordered only with LMI-2010)
3505

12 PULSE SCRTrigger Card

Request Callback

₹ 48500 / Piece Get Latest Price

Product Brochure
Voltage480V AC
BrandLIBRATHERM
Model Name/NumberLTC-24
Power Consumption25VA
Country of OriginMade in India

Minimum order quantity: 1 Piece

3 PHASE – 12 PULSE SCR TRIGGERING CARD (PHASE ANGLE CONTROL)  

 Description: 

Libratherm offers new version of SCR triggering cards model LTC-24 which is designed to fire 12 independent SCRs or six back-to-back connected SCRs using synchronized phase angle control technique. The card accepts analogue control signals of (0-5) / (0-10) VDC or (4-20) mA and provides proportional 12 x gate/cathode triggering pulses G1K1 to G12K12.  These pulses can be used to trigger SCRs up to 1000Amps with gate current upto 300mA. The card also provides built in regulated 5VDC supply to connect external potentiometer to manually control the SCR firing. The on card ramp up and ramp down settings allows gradual rise and fall of the voltage levels across the load.  The max/min power settings allow to increase or decrease AC/DC voltage level to the load. The current limit and over current trip settings allow user to limit the max. current through the load and in case of over current the trip relay is energized and thyristor firing is shut off.  

 The LTC-24 is useful for heating control applications to control three phase AC power across the heating coils or to control the star or delta connected transformer loads. The 12-pulse card has advantage over the 6-pulse card since for higher load carrying capacity, instead of using higher ratings of SCRs, two lower ratings of SCRs can also be used. For example, in case of AC to DC bridge rectifiers requiring 1000A DC current, instead of using six nos. 1000A SCR, twelve nos. of 500A SCRs can also be used. Similarly for AC to AC control applications two parallel configurations can be made using six pair of back-to-back connected SCRs in star or delta configuration

 For current limit and current trip features, LTC-24 accepts two external Load Current:5A CT inputs to monitor three phase-load current. These current values are internally compared for limit and trip features.

DC Power Supply For Sensor / Loop Powered Transmitter LPS-24

Request Callback

₹ 1250 / Piece Get Latest Price

Product Brochure
Output Voltage24VDC @ max.300mA,(7.5watt max)
BrandLibratherm
ModelLPS-24
Input Supply90-240VAC, 50/60Hz
TerminalsScrew-on type plug and socket for Input and Output termination.
Size or Mounting90 h x 60 w x 35 d mm. / Centre to Centre 72 mm using 2 x M3 screws.
Power ON IndicationRed LED turns ON and visible from front.
EnclosureSheet metal MS powder coated

Minimum order quantity: 1 Piece

Features:
  • Latest SMPS design
  • Stable and regulated 24VDC
  • Protected against Industrial RFI/EMI interferences.
  • Wide input supply of 90 to 240VAC
  • Built in overload protection.

Description:

Libratherm offers industrially proven and time tested 24VDC switch mode power supply to meet various industrial requirements. It is compact, sufficienly rated useful power source to power extenal devices like 24vdc operated solenoid valves, Sensors, 2 or 4 wire process transmitters like Pressure transmitters, temperature transmitters, flow transmitters. 24vdc operated signal isolators/convertors/instruments/actuator valves/lamps etc. To generate 24VDC logic pulse or level as Digital input to PLC, HMI, thyristor switch module or other such devices. This economical and low rating power supply often serves most of the applications where high power / bigger size 24VDC power supply is not required and hence user will have advantage of saving on cost and panel space.

Three Phase Heater Fail / Over Load Detection Module HFM-3

Request Callback

₹ 3500 / Number Get Latest Price

Product Brochure
ApplicationHFM-3-OVL (for over load detection) or HFM-3-OPL (for open load detection)
Model NumberHFM-3
Size110 x 110 x 50 mm
BrandLIBRATHERM
Available ConfigurationThree phase single heating zone or single phase 3 independent heating zone.
Reference SignalTo be derived from the external temperature controller in the form of 4-20mA/0-5V/DC pulse/Potential
Current FeedbackMax. 20A for each heater through built in CT or using external CT of 5A ratio.
Fault OutputRelay changeover contacts - 3 nos. of NO-C-NC contacts for 3 sets of heater loads, with LED indicati
Load TypeSuitable for resistive heating load single phase x 3 or three phase x 1
Aux Supply Voltage230VAC +/-10%, 50/60Hz @ max.4A
MountingDIN rail or stud mount.

Minimum order quantity: 1 Number

DESCRIPTION:

In the heating process, it is very important to ensure that the electrical heaters remain healthy, however over a period of time, practically heaters do have tendency to either go open due to break in the heating element or two close elements likely to get short with each other and comes in parallel thereby effective resistance drops and tend to draw current more than the normal rated current. When the heater goes open, it reduces the heating capacity and increases the burden on other healthy heating elements to achieve desired set temperature. When the heater shorts the current drawn increases and may lead to burning of contacts and connecting leads and wires and it may lead to fire hazard. To safeguard the process operation against such heater behavior, it is indispensable to monitor the status of heaters on continuous basis. The only way to detect the heater status is to monitor the current flowing through it.

HFM-3 is designed to detect the failure (open or short/over load) of any of the 3 independent or 3 phase heater load. Heater current per phase of max.20A can be allowed to pass through the individual in-built CTs (for higher load current external CT with 5A CT ratio can be used). User can pass the 3 individual load cable of max. 4 square mm through each of the 3 nos. of built-in CT.  The heater failure either open or short circuiting is detected by comparing Reference input command and the maximum current through each heater under normal condition with the desired set current, adjustable using on card presets marked P1, P2 and P3. When the current through the heater exceeds the set level of current, the respective on card relay energizes and respective LED will glow. This condition will remain true till the current through the heater falls below the set level of current and then relay will de-energize and LED will go off. HFM-3 works on single phase AC supply of 230VAC+/10% @ max. 4VA. It can be mounted on 35mm C rail or G rail.  While placing the order, user may specify the requirement type HFM-3-OVL (for over load detection) or HFM-3-OPL (for open load detection), based on the likelihood of heater fail condition, since, HFM-3 can detect any one condition at a time.

Transmitter For Vacuum Chamber

Request Callback

₹ 14000 / Unit Get Latest Price

Product Brochure
Output Value4-20mA
ApplicationVaccum Chamber machine
Input Value24 VDC.
EnclosureABS Plastic
IP RatingIP 65

Minimum order quantity: 1 Unit

T RH Transmitter without Display For Vacuum Chamber

Features:
  • Highly accurate T Rh sensor from Rotronic-Swiss
  • Duct Mount, Wall Mount and Vacuum version

Heater Failure Indicator

    Request Callback

    ₹ 9500 / Piece Get Latest Price

    Product Brochure

    PRODUCT DESCRIPTION:

     

    Libratherm offers a 3-phase heater status module (HSM-3). This module is customised and designed using a high speed 32-bit microcontroller to monitor the AC current flowing through 3-phase heaters. The actual current flowing per phase is displayed on a 3-digit display, which will scan all 3 phases in 3 seconds scan mode with the respective R Y B LEDs turning ON. The module accepts the current feedback from the external 3 CTs having a 5A ratio or can directly accept heater current per phase of max.25A. HSM-3 has built-in 3 x CTs to measure the heater current from each phase. The input heater/CT connectors are rated for 30A.

     

    The built in 32-bit microcontroller processes the heater current for the digital display and convert it to the MODBUS RTU format for transmitting the data over the RS-485 serial port.

     

    The front panel keyboard allow user to program the Slave ID of each module, high and low current set point for each phase and scale the current based on the external CT ratio. The front panel provides various LEDs indicating the per phase Heater current in Ampere, TX/RX indicating the serial data transmission, the status of input contact (DI) from the external temperature controller and status of output relay contact (DO) in case of heater current deviates from the high and low limits to indicate drop in the current as the heater failure condition. Under heater fail condition, the phase current will always reduce so low alarm can be used to detect the status. Whereas high alarm condition can be used, if the heater current exceeds the high set value. 

    How the Heater fault is detected?

     

    The above features make this model suitable to detect the heater status to identify whether heater is OK or gone open. For example, per phase 3 heaters each of 2KW @ 230VAC, is connected in parallel totalling 6KW per phase and 18KW @ 3 phase. Under normal condition when heaters are turned ON, the phase current will be 26A. If one of the heaters fails, the current will reduce by 1/3rd that is by 8.7A through that phase and reading will be 26A-8.7A = 17.3A. If the low set point is set to 20A, the internal relay will energise since the phase current is now less than 20A. This relay contact can activate the external audio-visual alarm to indicate that one of the heaters out of 9 heaters has failed or gone open or this DO can be used as DI to the external PLC. The heater current is logically compared only if the input contact (DI) is closed.

     

    The three phase heater current values, status of DI/DO are also transmitted over                  RS-485/MODBUS protocol for external PLC/HMI to interpret the heater failure condition. MODBUS address registers are shared with the user in the operation manual.

     

     

    The module HSM-3 works on an external (18-36) VDC power supply and can be wall-mounted inside the panel. The electronics PCB is enclosed in a suitable powder-coated metal enclosure of size 115(H) x 195(W) x 75 (D) in mm. 

    Where this Module can be used?

     

    The HSM-3 module finds its applications in continuous production machines incorporating several 3-phase heater banks and where failures of heaters affect the process line output and it is required to pinpoint the heater failure location and to allow the operator to replace the failed heater in the shortest possible down-time. It detects heater failures by allowing online monitoring of the current flowing through each heater over RS-485 on the PLC/HMI screen or by providing the digital output (potential free contact) as described above.

     

    X

    Contact Us

    Kamlesh Panchal (Managing Director)
    Libratherm Instruments Private Limited
    No. 401-403, Diamond Industrial Estate, Ketki Pada Road
    Mumbai - 400068, Maharashtra, India

    Get Directions
    Send Email
    Share: